TPS1100 - Appl. Prog. Ref. Manual 2.2.0en

Orientation and Height Transfer

User Disp
YES:
The same display mask as the
one used in the system measure-
ment dialog (MEAS) is used for
measurements with "Orientation and
Height Transfer".

NO: The "Orientation and Height
Transfer" default display applies.

Log File
ON
, records measurements in a Log-
File. The format is described in
chapter "Log file".

Log FlName
Enter the Log File Name.

Meas. Job
Selection of the measurement job for
recording measurements.

Data Job
Selection of the data job containing
the fix point coordinates (control
data).

Store the current
configuration and proceed to

the dialog "TARGET POINT".

Set the values to default.

Displays date and version.

Exit the program.

Configuration Editor, continued

Ht Acc TP
Height accuracy of the target points.
The entered value, is used as an "a
priori" accuracy in the calculation.
The height is regarded as "error
free", if the computed standard
deviation is within twice the entered
value.

Pos Acc TP
Position accuracy of the target points.
The entered value, is used as an "a
priori" accuracy in the calculation.
The position is regarded as "error
free", if the computed standard
deviation is within twice the entered
value.

Two Faces
YES
for dual-face measurement,
NO for single-face.