TPS1100 - Appl. Prog. Ref. Manual 2.2.0en

Resection

If "Log File" is set to "ON" the
measurements and the results are
stored in the ASCII-file specified
within the "Configuration Editor". This
file is created in the directory LOG on
the memory card. Subsequently, you
can read the memory card on your
PC and obtain a hard copy of the
Log-file.

Data will always be
appended to the specified

Log-file.

The Log-file contains the following
information:

Header
The header line will contain the
program used, information about the
instrument, the name of the data file
as well as date and time.

Log File

Record
For each measurement, a record will
be stored containing:
Station coordinates and orientation
correction, standard deviation for
Easting, Northing, Height of station
and orientation correction.
The residuals for horizontal angles,
heights and measured distances are
also listed.