TPS1100 - Appl. Prog. Ref. Manual 2.2.0en

Resection

Dual-face Measurement

In the dual-face mode, the program
will prompt for measurements in both
faces. When both measurements are
taken, the program will check the
difference between the two. If the
difference in angle is within 27'
(0.5 gon)
and the difference of two
measured distances is within 0.5 m
(1.64 ft)
, the observations will be
averaged.
These tolerances are used to avoid
errors in target identification.
If exceeded an error message will be
displayed.

Store the current
configuration and proceed to

the dialog "STATION DATA".

Set the value to the default

Displays date and version.

Exit the program.

Log FlName
Enter the Log File Name.

Meas. Job
Selection of the measurement job for
recording measurements.

Data Job
Selection of the data job containing
the fix point coordinates (control
data).

UserDisp.
YES The same display mask as the

one used in the system
measurement dialog (MEAS)
is used for measurements with
"RESECTION".

NO

The "RESECTION" default
display applies.

Log File
Set to ON, the program will record
measurement data in a log file as
described in

chapter "Log File".

Configuration Editor, continued