129

TPS1100 - Appl. Prog. Ref. Manual 2.2.0en

Traverse

The instrument is set up on
previously measured traverse point.
A measurement (distance measure-
ment is optional) is made to the last
traverse point.

This dialog corresponds to the
TPS1100 Professional series
"MEASURE" dialog. After the
function has been performed, the
station coordinates and orientation
are set in the instrument.

Occupy station

Station Id
Station identifier

Backsight
Backsight identifier

Simultaneously measure and
record data in the Meas Job.

Measure a distance

1

and record data in the

Meas Job.

Measure a distance
without recording in

the Meas Job.

Proceed to the dialog
"TRAVERSE MENU".

Enter target data.
(see User Manual)

Toggles to select the last
measured sideshot, or the

last measured traverse point, as the
new station.

2

Change the theodolite
face.

1

Distance measurement is optional.

2

Only active if a sideshot point was
measured.

I<>II

QUIT

Slope Dist:

----- m

Height Dif:

----- m

East

:

----- m

North

:

----- m

Elevation :

----- m

Trav\ Occupy Traverse Pt

Station Id:

2

Backsight :

1

Inst. Ht. :

1.300 m

Refl. Ht. :

1.300 m

Hz

:

249°10'20''

V

:

90°19'52''

MC

ALL

DIST

REC

CONT TARGT

SS