Free Station

User Disp
YES The same display mask as the

one used in the system
measurement dialog (MEAS)
is used for measurements with
"Free Station".

NO

The "Free Station" default
display applies.

Log File
ON, records measurements in a Log-
File.The format is described on
chapter Log File.

Log FlName
Enter the Log File Name

Meas. Job
Selection of the measurement job for
recording measurements.

Data Job
Selection of the data job containing
the fix point coordinates (control
data).

Store the current
configuration and proceed to

the dialog "STATION DATA".

Set the values to default.

Display software-version

Exit the program.

Dual-face Measurement

In the dual-face mode, the program
will prompt for measurements in both
faces. When both measurements are
taken, the program will check the
difference between the two. If the
difference in angle is within 27'
(0.5 gon)
and the difference of two
measured distances is within 0.5 m
(1.64 ft)
, the observations will be
averaged. These tolerances are used
to avoid errors in target identification.
If exceeded an error message will be
displayed.