TPS1100 - Appl. Prog. Ref. Manual 2.2.0en

Sets of Angles

Press after all settings are
correct and go to the

Measurement Dialog.

(Optional) Press to create a
list of up to ten target points.

Subsequent measurements may then
be made by selecting the target point
from this list.

(Not available until a list of
target points has been

defined.) Press to select the previous
point on the list.

(Not available until a list of
target points has been

defined.) Press to select the next
point on the list.

Press when all target points
have been measured in Face

II or to abort measurement.

Seq. no.
Displays the sequential number of
the point currently being measured.

Point Id
Input the Point Id of the point
currently being measured.

Refl. Ht.
(Optional, but necessary for the
program to correctly calculate the
elevation of the target point.) Input
the Reflector Height of the point
currently being measured.

Auto Meas.
Automatic Measurement option,
available only with motorized
instruments. Select ON or OFF as
desired.

If OFF, motorized instruments must
be manually pointed to this target
point in further sets.

Measure Mode , continued

If ON, motorized instruments will
automatically turn toward this target
point in further sets.

If ON and the target is a prism,
motorized instruments with ATR will
automatically turn toward, fine point
and measure to this target point.

Prism Type
(Optional, but necessary for the
instrument to correctly measure the
distance to the target point.) Select
the type of prism at this target point.

PrismConst
Display only of the offset of the
current Prism Type. Will be updated
if the Prism Type is changed.