Measure mode, Calculation, Measure mode calculation – Leica Geosystems TPS1100 Professional Series - Reference Manual User Manual

Page 56: Free station measure mode

Advertising
background image

56

TPS1100 - Appl. Prog. Ref. Manual 2.2.0en

Free Station

Measure Mode

This dialog is similar to the
TPS1100's basic "MEASURE MODE"
dialog. Once a measurement is
taken, the program will return to the
dialog "Target Point" to acquire the
next point for measuring.

If the station coordinates can be
calculated successfully from the first
few measurements, the

Hz and

V

values are displayed for further
entered target points. Motorized
theodolites will automatically drive the
telescope to the target point.

Simultaneously measure and
record data in the active

measurement job. Return to the
dialog "TARGET POINT".

Measure a distance.

Record the measurement in
the active measurement job.

Return to the dialog "Target Point".

Accept the measurement and
return to the dialog "TARGET

POINT".

Enter target data.
(see User Manual)

Change the theodolite
face.

Exit the program.

Calculation

Calculates the 3D station coordinates
and orientation as well as the
standard deviation of the results.

Station Id
Point number assigned to the station

No. of Pts
Number of points measured

FreSt\

Measure

Point Id

:

12

Hz

:

286°55'50''

V

:

91°16'20''

Refl. Ht. :

1.500 m

Slope Dist:

22.039 m

∆∆∆∆∆

Hz

:

----- m

MC

I<>II

QUIT

ALL

DIST

REC

CONT TARGT

PLOT

QUIT

Hz Ori.

:

2°12'34''

σσσσσ

East

:

0.003 m

σσσσσ

North

:

0.005 m

σσσσσ

Elev.

:

0.005 m

σσσσσ

Hz Ori.

:

0°00'03''

Calc Scale:

YES

Scale

:

0.999956

FreSt\ Results (L.Sqrs)

Station Id:

1

No. of Pts:

6

Inst. Ht. :

1.635

East

:

2134.234

North

:

4231.365

Elevation :

580.643

MC

SET

STORE MEAS

MORE

COMP

Advertising