Configuration, Logfile – Leica Geosystems TPS1100 Professional Series - Reference Manual User Manual

Page 264

Advertising
background image

264

TPS1100 - Appl. Prog. Ref. Manual 2.2.0en

Configuration

Start the "Configuration Editor" from
the "Main Menu".

REFP\ Configuration

Max

∆∆∆∆∆

d +/-:

0.300

m

Log File

:

ON

Log FlName:

Refplane.log

Meas job

:File01.GSI A:

Data job

:File01.GSI A:

MC

CONT ADD P

OFFS

MORE

NEW

Max

∆∆∆∆∆

d

Maximum allowed perpendicular
deviation of plane definition point
from calculated plane.

Log File
Set to ON, the program records
measurement data to a log file.

Should be ON for local
systems, since GSI file only

contains instrument coordinates. Log
file saves local system coordinates.

Log FlName
Enter the Logfile name.

Meas job
Sets the measurement job to record
data to.

Data job
Sets the data job containing fixpoint
coordinates.

Store the configuration and
return to “Main Menu”.

Set the values to default.

Display date and version no. of
running application.

Logfile

If Logfile is set to ON the
measurements and the results are
stored in the ASCII-file specified
within the "Configuration". This file is
created in the directory LOG on the
memory card. Subsequently, you can
read out the memory card and obtain
a hard copy of the Logfile.

If ON, data is always
added to the specified

Log-file.

The Logfile contains the following
information:

Header
The header line contains the program
used, information about the
instrument, the name of the data file
as well as date and time.

Configuration
Each modification of the reference
plane is stored.

Advertising