TPS1100 - Appl. Prog. Ref. Manual 2.2.0en

Auto Record

Three automatic recording modes
are available:

• Time Interval,
• Distance Interval

and

• Stable Position.

The intervals are applied relative to
the last recorded position, whether
triggered manually or automatically.
In all cases, the measurement data
will be recorded using the REC Mask
you have specified.

Configuration Options, continued

TimeInterv
When this mode is ON and the TCA-/
TCRA-instrument is following a prism
in the tracking measurement mode,
measurement data will be recorded
automatically whenever the time
since the last recorded measurement
data exceeds the time interval shown
here, i.e. every 5 seconds.

DistInterv
When this mode is ON and the TCA-/
TCRA-instrument is following a prism
in the tracking measurement mode,
measurement data will be recorded
automatically whenever the three
dimensional slope distance from the
last recorded measurement data
exceeds the distance shown here,
i.e. 5 meters.

Stable Pos,
StableTime
When this mode is ON and the TCA-/
TCRA-instrument is following a prism
in the tracking measurement mode,
measurement data will be recorded
automatically whenever the prism
remains within a circle of the radius
for the length of time shown here, i.e.
the position remains constant within 5
centimeters for 2 seconds.

AREC\

Configuration

TimeInterv:

5sec

DistInterv:

5.000 m

Stop Pos. :

0.050 m

Stop Time :

2sec

CONT

TIME DIST ST&GO INFO

MC

QUIT