60

TPS1100 - Appl. Prog. Ref. Manual 2.2.0en

Free Station

Scroll to the measurements
of the following point.

Measure more point. Return
to dialog "Target Point".

Delete a point from the set of
measurements . You can now

measure a new point in its place.

Return to the results dialog
without changes.

Exit the program.

Plot

Generates a plot showing the
measurement configuration. The
station point is in the center and the
top of the sketch shows the direction
of Grid north. The sketch is true in
angular but not true in distances.
Points are numbered sequentially in
the order in which they were
measured. Points not used in the
calculation are marked with a dotted
line.

Recalculate the solution and
return to the dialog

"RESULTS".

Measure more points. The
program will recall the

"TARGET POINT" dialog.

Toggle any point ON or
OFF by pressing the

numeric key corresponding to the
sequence number of the point.

Note, that

represents point 10.

...

More Information, continued

FreSt\

PLOT

MC

I<>II

RECLC

MEAS

1

5

4

3

2