141

TPS1100 - Appl. Prog. Ref. Manual 2.2.0en

Local Resection

Data Job
Selection of the data job containing
the fix point coordinates (control
data).

Store the current
configuration and proceed to

the dialog "STATION DATA".

Set the value to the default.

Displays date and version of
the running application.

Dual-face Measurement

In the dual-face mode, the program
will prompt for measurements in both
faces. When both measurements are
taken, the program will check the
difference between the two. If the
difference in angle is within 27'
(0.5 gon)
and the difference of two
measured distances is within 0.5 m
(1.64 ft)
, the observations will be
averaged. These tolerances are used
to avoid errors in target identification.
If exceeded an error message will be
displayed.