Sets of Angles

Press to measure to the
displayed target point in the

displayed face.

Press to measure to the
previous target point in the

displayed face. You may measure
points out of sequence, but this may
have undesirable effects in your post-
processing software.

Press to measure to the next
target point in the displayed

face. You may measure points out of
sequence, but this may have
undesirable effects in your post-
processing software.

Press when all target points
have been measured in Face

II or to abort measurement.

• Measure Further Set

After finishing the first set, select
Measure Further Set again. You must
repeat the above procedure to
measure at least one more set. You
may measure more than one
additional set, up to the maximum
number of pointings supported by
Sets of Angles (64 Face I / Face II
pointings to targets.)

If you have a motorized instrument,
you will be able to specify the number
of additional sets, and the instrument
will turn to each target point in
sequence until all the additional sets
have been measured. TCA- and
TCRA-instruments will automatically
measure to all target points that have
the Auto. Meas. parameter set to ON.

Set no.
Displays the number of the set
currently being measured.

If you have a non-motorized
instrument, you will select Measure
Further Set after each set is
completed, until all additional sets
have been measured.

The Telescope Positioning dialog will
help you find the target points in
sequence.

Measure Mode, continued

SETS\

Measure Set

Set No.

:

1

Seq. No.

:

1

Face

:

I

Point Id

:

501

Refl. Ht. :

1.300 m

Auto Meas.:

OFF

MC

QUIT

MEAS

<--

-->

DONE

Advertising