Configuration, Configuration editor, Sets of angles – Leica Geosystems TPS1100 Professional Series - Reference Manual User Manual

Page 116: Examples and used formulae, continued

Advertising
background image

116

TPS1100 - Appl. Prog. Ref. Manual 2.2.0en

Sets of Angles

v

2

(N-1) (s-1)

The "Configuration Editor" sets
parameters for further program
operations:

Meas Method
> <

All targets have to be observed

for face II in opposite order to the
observations in face I.

Average of the differences for
horizontal directions.

Standard deviation of one horizontal
direction observed in two faces.

Used formulae and designations

a

= In both faces observed and

averaged direction.

b

= In both faces averaged and

reduced direction of a set

d

= Final averaged direction from

all sets.

r

= Difference between a final

direction averaged from all
sets and a single direction of
a set.

q

= Average of the differences (r).

v

= Residuals.

s

= Number of sets

N

= Number of targets.

r

= d - b

v

= r + q for horizontal directions

v

= d - a for vertical directions

Standard deviation of one vertical
direction observed in two faces.

Standard deviation of an averaged
direction from all sets.

Configuration

Configuration Editor

Start the "Configuration Editor" from
the "SETS MENU" dialog.

Examples and used formulae, continued

mR=

v

2

N*s-1

mR=

r

q =

N

mR

q =

s

SETS\

Configuration

MeasMode

:

<>

User Disp.:

NO

Hz Tol.

:

0°00’16’’

V Tol.

:

0°00’16’’

Log File

:

OFF

Log FlName:

SETS.LOG

CONT

DEFLT INFO

MC

QUIT

Meas Job

:

FILE01.GSI

Data Job

:

FILE02.GSI

Advertising