Configuration, Configuration editor, Sets of angles – Leica Geosystems TPS1100 Professional Series - Reference Manual User Manual
Page 116: Examples and used formulae, continued

116
TPS1100 - Appl. Prog. Ref. Manual 2.2.0en
Sets of Angles
∑
v
2
(N-1) (s-1)
The "Configuration Editor" sets
parameters for further program
operations:
Meas Method
> <
All targets have to be observed
for face II in opposite order to the
observations in face I.
Average of the differences for
horizontal directions.
Standard deviation of one horizontal
direction observed in two faces.
Used formulae and designations
a
= In both faces observed and
averaged direction.
b
= In both faces averaged and
reduced direction of a set
d
= Final averaged direction from
all sets.
r
= Difference between a final
direction averaged from all
sets and a single direction of
a set.
q
= Average of the differences (r).
v
= Residuals.
s
= Number of sets
N
= Number of targets.
r
= d - b
v
= r + q for horizontal directions
v
= d - a for vertical directions
Standard deviation of one vertical
direction observed in two faces.
Standard deviation of an averaged
direction from all sets.
Configuration
Configuration Editor
Start the "Configuration Editor" from
the "SETS MENU" dialog.
Examples and used formulae, continued
mR=
∑
v
2
N*s-1
mR=
∑
r
q =
N
mR
q =
√
s
SETS\
Configuration
MeasMode
:
<>
User Disp.:
NO
Hz Tol.
:
0°00’16’’
V Tol.
:
0°00’16’’
Log File
:
OFF
Log FlName:
SETS.LOG
CONT
DEFLT INFO
MC
QUIT
Meas Job
:
FILE01.GSI
Data Job
:
FILE02.GSI