GARP participant for each port.

Leave Time (centiseconds) -

Specify the time to wait after receiving an unregister request for a VLAN or multicast

group before deleting the associated entry, in centiseconds. This allows time for another station to assert

registration for the same attribute in order to maintain uninterrupted service. Enter a number between 20 and 600

(0.2 to 6.0 seconds). The factory default is 60 centiseconds (0.6 seconds). An instance of this timer exists for each

GARP participant for each port.

Leave All Time (centiseconds) -

The Leave All Time controls how frequently LeaveAll PDUs are generated. A

LeaveAll PDU indicates that all registrations will shortly be deregistered. Participants will need to rejoin in order to

maintain registration. The Leave All Period Timer is set to a random value in the range of LeaveAllTime to

1.5*LeaveAllTime. The timer is specified in centiseconds. Enter a number between 200 and 6000 (2 to 60

seconds). The factory default is 1000 centiseconds (10 seconds). An instance of this timer exists for each GARP

participant for each port.