2.2.2 Rack Mounting

To install the WGS3 LAYER 3 Switch in a 19-inch standard rack, please follows the instructions described below.

Step1:

Place the WGS3 LAYER 3 Switch on a hard flat surface, with the front panel positioned towards the front side.

Step2:

Attach the rack-mount bracket to each side of the WGS3 LAYER 3 Switch with supplied screws attached to the package.

Figure 2-4 shows how to attach brackets to one side of the WGS3 LAYER 3 Switch.

Figure 2-4

Attach brackets to the WGS3 LAYER 3 Switch.

Caution:

You must use the screws supplied with the mounting brackets. Damage caused to the parts by using incorrect screws

would invalidate the warranty.

Step3:

Secure the brackets tightly.

Step4:

Follow the same steps to attach the second bracket to the opposite side.

Step5:

After the brackets are attached to the WGS3 LAYER 3 Switch, use suitable screws to securely attach the brackets to the

rack, as shown in Figure 2-5.

Figure 2-5

Mounting the WGS3 LAYER 3 Switch in a Rack

Step6:

Proceeds with the steps 4 and steps 5 of session 2.2.1 Desktop Installation to connect the network cabling and supply

power to the WGS3 LAYER 3 Switch.