Low pass filter enable/disable, Low pass filter enable/disable -90 – Rockwell Automation 2098-DSD-xxx Ultra3000 Host Commands for Serial Interface User Manual

Page 106

Advertising
background image

Publication 2098-RM003A-EN-P October 2001

2-90

Command Reference

Low Pass Filter Enable/Disable

Format:

:aa02Efddcc<cr>

Parameter
Code:

0x02E

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x04 = Data Below Minimum
0x05 = Data Above Maximum
0x08 = Invalid Function Code

Data Fields:

dd

Enable/disable of the current command low pass
filter, where:
0x00: Disable low pass filter
0x01: Enable low pass filter

Minimum
Value:

0x0

Maximum
Value:

0x1

Default:

0x0

Advertising