Analog current scale, Analog current scale -22 – Rockwell Automation 2098-DSD-xxx Ultra3000 Host Commands for Serial Interface User Manual

Page 38

Advertising
background image

Publication 2098-RM003A-EN-P October 2001

2-22

Command Reference

Analog Current Scale

Format:

:aa119fddddcc<cr>

Parameter
Code:

0x119

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x04 = Data Below Minimum
0x05 = Data Above Maximum
0x08 = Invalid Function Code

Data Fields:

dddd

Analog current scale, in units of percentage of the
minimum of the motor intermittent current rating
and drive intermittent current rating, per 10 Volts.

Minimum
Value:

-200

-200

Maximum
Value:

200

200

Default:

100

100