Publication 2098-RM003A-EN-P October 2001

2-74

Command Reference

Force Constant

Electrical Cycle Length

Format:

:aa0E2fddddcc<cr>

Parameter
Code:

0x0E2

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x04 = Data Below Minimum
0x08 = Invalid Function Code

Data Fields:

dddd

Force constant of a linear motor, in units of N-m/
Amp * 16.

Minimum
Value:

0x0001

Maximum
Value:

0xFFFF

Default:

16

Format:

:aa0E3fddddcc<cr>

Parameter
Code:

0x0E3

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x04 = Data Below Minimum
0x05 = Data Above Maximum
0x08 = Invalid Function Code

Data Fields:

dddd

Length of an electrical cycle for a linear motor, in
units of millimeters*10.

Minimum
Value:

100

Maximum
Value:

10000

Default:

300