Velocity error time, User current limit, Velocity error time -121 user current limit -121 – Rockwell Automation 2098-DSD-xxx Ultra3000 Host Commands for Serial Interface User Manual

Page 137: Velocity error time user current limit

Advertising
background image

Publication 2098-RM003A-EN-P October 2001

Command Reference

2-121

Velocity Error Time

User Current Limit

Format:

:aa027fddddcc<cr>

Parameter
Code:

0x027

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x08 = Invalid Function Code

Data Fields:

dddd

Velocity error time, in units of mS. If the velocity
error exceeds the velocity error limit for greater than
the velocity error time, a fault will be generated.

Minimum
Value:

0x0000

Maximum
Value:

0xFFFF

Default:

100

Format:

:aa031fddddcc<cr>

Parameter
Code:

0x031

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x08 = Invalid Function Code

Data Fields:

dddd

User current limit, in units of Amps*128. If the
average current exceeds this value a fault will be
generated.

Minimum
Value:

0x0000

Maximum
Value:

0x7FFF

Default:

0x7FFF

Advertising