Setpoint velocity, Setpoint acceleration, Reset faults – Rockwell Automation 2098-DSD-xxx Ultra3000 Host Commands for Serial Interface User Manual
Page 29
![background image](/manuals/580675/29/background.png)
Publication 2098-RM003A-EN-P October 2001
Command Reference
2-13
Setpoint Velocity
Setpoint Acceleration
Reset Faults
Format:
:aa06Dfddddddddcc<cr>
Parameter
Code:
0x06D
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x04 = Data Below Minimum
0x08 = Invalid Function Code
Data Fields:
dddddddd
Setpoint velocity, in units of counts/second.
Minimum
Value:
0x80000001
Maximum
Value:
0x7FFFFFFF
Default:
0x0000
Format:
:aa06Efddddddddcc<cr>
Parameter
Code:
0x06E
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x05 = Data Above Maximum
0x08 = Invalid Function Code
Data Fields:
dddddddd
Setpoint acceleration, in units of counts/sec/sec.
Minimum
Value:
0x00000000
Maximum
Value:
0x7FFFFFFF
Default:
100,000
Format:
:aa06Ffcc<cr>
Parameter
Code:
0x06F
Valid Function
Codes:
0x1 = Write Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields:
None