Overtravel commands, Positive soft position limit, Negative soft position limit – Rockwell Automation 2098-DSD-xxx Ultra3000 Host Commands for Serial Interface User Manual

Page 67: Overtravel commands -51

Advertising
background image

Publication 2098-RM003A-EN-P October 2001

Command Reference

2-51

Overtravel Commands

Positive Soft Position Limit

Negative Soft Position Limit

Format:

:aa0D8fddddddddcc<cr>

Parameter
Code:

0x0D8

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x05 = Data Above Maximum
0x08 = Invalid Function Code

Data Fields:

dddddddd

Position that, when exceeded positively, will cause a
deceleration to zero velocity.

Minimum
Value:

0x80000001

Maximum
Value:

0x7FFFFFFF

Default:

0x7FFFFFFF

Format:

:aa0D9fddddddddcc<cr>

Parameter
Code:

0x0D9

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x06 = Data Below Minimum
0x08 = Invalid Function Code

Data Fields:

dddddddd

Position that, when exceeded negatively, will cause
a deceleration to zero velocity.

Minimum
Value:

0x80000001

Maximum
Value:

0x7FFFFFFF

Default:

0x80000001

Advertising