Positive peak current command, Negative peak current command, Bus voltage – Rockwell Automation 2098-DSD-xxx Ultra3000 Host Commands for Serial Interface User Manual
Page 131
![background image](/manuals/580675/131/background.png)
Publication 2098-RM003A-EN-P October 2001
Command Reference
2-115
Positive Peak Current Command
Negative Peak Current Command
Bus Voltage
Format:
:aa089fddddcc<cr>
Parameter
Code:
0x089
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields:
dddd
Peak positive current command, in units of
Amps*128.
Format:
:aa08Afddddcc<cr>
Parameter
Code:
0x08A
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields:
dddd
Peak negative current command, in units of
Amps*128.
Format:
:aa08Bfddddcc<cr>
Parameter
Code:
0x08B
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields:
dddd
Bus voltage, after filtering, in units of Volts.