Publication 2098-RM003A-EN-P October 2001

Command Reference

2-115

Positive Peak Current Command

Negative Peak Current Command

Bus Voltage

Format:

:aa089fddddcc<cr>

Parameter
Code:

0x089

Valid Function
Codes:

0x0 = Read Working Value

Valid Exception
Codes:

0x08 = Invalid Function Code

Data Fields:

dddd

Peak positive current command, in units of
Amps*128.

Format:

:aa08Afddddcc<cr>

Parameter
Code:

0x08A

Valid Function
Codes:

0x0 = Read Working Value

Valid Exception
Codes:

0x08 = Invalid Function Code

Data Fields:

dddd

Peak negative current command, in units of
Amps*128.

Format:

:aa08Bfddddcc<cr>

Parameter
Code:

0x08B

Valid Function
Codes:

0x0 = Read Working Value

Valid Exception
Codes:

0x08 = Invalid Function Code

Data Fields:

dddd

Bus voltage, after filtering, in units of Volts.