Poles / Revolution

Hall Offset

Format:

:aa041fddcc<cr>

Parameter
Code:

0x041

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x01 = Invalid Data
0x03 = EEPROM Write Error
0x05 = Data Above Maximum
0x08 = Invalid Function Code

Data Fields:

dd

Poles per revolution of a rotary motor. Only even
values are acceptable.

Minimum
Value:

2

Maximum
Value:

100

Default:

8

Format:

:aa042fddddcc<cr>

Parameter
Code:

0x042

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x05 = Data Above Maximum
0x08 = Invalid Function Code

Data Fields:

dddd

Hall offset, in units of electrical degrees.

Minimum
Value:

0

Maximum
Value:

359

Default:

0