Home sensor polarity, Homing creep velocity, Home sensor polarity -59 homing creep velocity -59 – Rockwell Automation 2098-DSD-xxx Ultra3000 Host Commands for Serial Interface User Manual

Page 75: Home sensor polarity homing creep velocity

Advertising
background image

Publication 2098-RM003A-EN-P October 2001

Command Reference

2-59

Home Sensor Polarity

Homing Creep Velocity

Format:

:aa0CBfddcc<cr>

Parameter
Code:

0x0CB

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x05 = Data Above Maximum
0x08 = Invalid Function Code

Data Fields:

dd

Polarity of the home sensor, where:
0x00: Inactive-to-active transition
0x01: Active-to-inactive transition

Minimum
Value:

0x00

Maximum
Value:

0x01

Default:

0x00

Format:

:aa0CCfddddddddcc<cr>

Parameter
Code:

0x0CC

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x04 = Data Below Minimum
0x05 = Data Above Maximum
0x08 = Invalid Function Code

Data Fields:

dddddddd

Homing creep velocity, in units of counts/second.

Minimum
Value:

0x00000001

Maximum
Value:

0x7FFFFFFF

Default:

10,000

Advertising