Command Reference

2-7

Up to Speed Limit

Forward Current Limit

Format:

:aa025fddddddddcc<cr>

Parameter
Code:

0x025

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x05 = Data Above Maximum
0x08 = Invalid Function Code

Data Fields:

dddddddd

Up to speed limit, in units of counts/second

Minimum
Value:

0x00000000

Maximum
Value:

0x7FFFFFFF

Default:

100,000

Format:

:aa02Ffddcc<cr>

Parameter
Code:

0x02F

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x05 = Data Above Maximum
0x08 = Invalid Function Code

Data Fields:

dd

Forward current limit, in percentage of the minimum
of the motor intermittent current rating and drive
intermittent current rating.

Minimum
Value:

0

Maximum
Value:

100

Default:

100