Motor Flux Saturation

Format:

:aa0E5fnnddcc<cr>

Parameter
Code:

0x0E5

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
0xA = Read Minimum Array Index Value
0xB = Read Maximum Array Index Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x04 = Data Below Minimum
0x07 = Invalid Array Index
0x08 = Invalid Function Code

Data Fields:

nn

Array index for the flux saturation table, where:
0x00 specifies the value at 12.5% of motor peak
current
0x01 specifies the value at 25.0% of motor peak
current
0x02 specifies the value at 37.5% of motor peak
current
0x03 specifies the value at 50.0% of motor peak
current
0x04 specifies the value at 62.5% of motor peak
current
0x05 specifies the value at 75.0% of motor peak
current
0x06 specifies the value at 87.5% of motor peak
current
0x07 specifies the value at 100% of motor peak
current

dd

Flux saturation value, scaled so a value of 255
indicates no saturation, and a value of 64 indicates
75% saturation.

Minimum
Value:

0x01

Maximum
Value:

0xFF

Minimum Array
Index Value:

0x00

Maximum Array
Index Value:

0x07

Default:

0xFF