Motor intermittent current, Motor continuous current – Rockwell Automation 2098-DSD-xxx Ultra3000 Host Commands for Serial Interface User Manual

Page 79

Advertising
background image

Publication 2098-RM003A-EN-P October 2001

Command Reference

2-63

Motor Intermittent Current

Motor Continuous Current

Format:

:aa039fddddcc<cr>

Parameter
Code:

0x039

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x04 = Data Below Minimum
0x05 = Data Above Maximum
0x08 = Invalid Function Code

Data Fields:

dddd

Motor intermittent current rating, in units of
Amps*128.

Minimum
Value:

0x0001

Maximum
Value:

0x7FFF

Default:

2560

Format:

:aa03Afddddcc<cr>

Parameter
Code:

0x03A

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x04 = Data Below Minimum
0x05 = Data Above Maximum
0x08 = Invalid Function Code

Data Fields:

dddd

Motor continuous current rating, in units of
Amps*128.

Minimum
Value:

0x0001

Maximum
Value:

0x7FFF

Default:

640