Position comparator polarity, Position comparator polarity -15 – Rockwell Automation 2098-DSD-xxx Ultra3000 Host Commands for Serial Interface User Manual
Page 31

Publication 2098-RM003A-EN-P October 2001
Command Reference
2-15
Position Comparator Polarity
Format:
:aa15Efnnddcc<cr>
Parameter
Code:
0x15E
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
0xA = Read Minimum Array Index Value
0xB = Read Maximum Array Index Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x04 = Data Below Minimum
0x05 = Data Above Maximum
0x07 = Invalid Array Index
0x08 = Invalid Function Code
Data Fields:
nn
Array index
dd
Position comparator polarity, where:
0 = Active for positions greater than the position
comparator value.
1 = Active for positions less than the position
comparator value.
Minimum Array
Index Value:
0x00
Maximum Array
Index Value:
0x01
Minimum
Value:
0x00
Maximum
Value:
0x01
Default:
0x00