Drive enable/disable, Setpoint current, Drive enable/disable -12 setpoint current -12 – Rockwell Automation 2098-DSD-xxx Ultra3000 Host Commands for Serial Interface User Manual
Page 28: Drive enable/disable setpoint current

Publication 2098-RM003A-EN-P October 2001
2-12
Command Reference
Drive Enable/Disable
Setpoint Current
Format:
:aa06Bfddcc<cr>
Parameter
Code:
0x06B
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x08 = Invalid
Function Code
Data Fields:
dd
Software enable disable control, where:
0x00: Disable drive
0x01: Enable drive.
Minimum
Value:
0x00
Maximum
Value:
0x01
Default:
0x01
Format:
:aa06Cfddddcc<cr>
Parameter
Code:
0x06C
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x04 = Data Below Minimum
0x08 = Invalid Function Code
Data Fields:
dddd
Setpoint current setting, in units of Amps*128.
Minimum
Value:
0x8001
Maximum
Value:
0x7FFF
Default:
0x0000