Publication 2098-RM003A-EN-P October 2001

2-12

Command Reference

Drive Enable/Disable

Setpoint Current

Format:

:aa06Bfddcc<cr>

Parameter
Code:

0x06B

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x08 = Invalid
Function Code

Data Fields:

dd

Software enable disable control, where:
0x00: Disable drive
0x01: Enable drive.

Minimum
Value:

0x00

Maximum
Value:

0x01

Default:

0x01

Format:

:aa06Cfddddcc<cr>

Parameter
Code:

0x06C

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x04 = Data Below Minimum
0x08 = Invalid Function Code

Data Fields:

dddd

Setpoint current setting, in units of Amps*128.

Minimum
Value:

0x8001

Maximum
Value:

0x7FFF

Default:

0x0000