Indexing operating mode commands, Auto-start indexing, Start index – Rockwell Automation 2098-DSD-xxx Ultra3000 Host Commands for Serial Interface User Manual

Page 54: Indexing operating mode commands -38, Auto-start indexing -38 start index -38, Auto-start indexing start index

Advertising
background image

Publication 2098-RM003A-EN-P October 2001

2-38

Command Reference

Indexing Operating Mode
Commands

Auto-start Indexing

Start Index

Format:

:aa058fddcc<cr>

Parameter
Code:

0x058

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x05 = Data Above Maximum
0x08 = Invalid Function Code

Data Fields:

dd

Enable/disable control for auto-start indexing,
where:
0x00: Disable auto-start indexing
0x01: Enable auto-start indexing.

Minimum
Value:

0x00

Maximum
Value:

0x01

Default:

0x00

Format:

:aa070fcc<cr>

Parameter
Code:

0x070

Valid Function
Codes:

0x1 = Write Working Value

Valid Exception
Codes:

0x08 = Invalid Function Code

Data Fields:

None

Advertising