Boot firmware version, Reset user parameters to factory defaults, Drive name – Rockwell Automation 2098-DSD-xxx Ultra3000 Host Commands for Serial Interface User Manual

Page 20

Advertising
background image

Publication 2098-RM003A-EN-P October 2001

2-4

Command Reference

Boot Firmware Version

Reset User Parameters to Factory Defaults

Drive Name

Format:

:aa003fvvrrcc<cr>

Parameter
Code:

0x003

Valid Function
Codes:

0x0 = Read Working Value

Valid Exception
Codes:

0x08 = Invalid Function Code

Data Fields:

vv
rr

Major boot firmware version.
Minor boot firmware revision.

Format:

:aa004fcc<cr>

Parameter
Code:

0x004

Valid Function
Codes:

0x1 = Write Working Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x06 = Command Disabled when Drive is Enabled
0x08 = Invalid Function Code

Data Fields:

None

Format:

:aa006fdd…ddcc<cr>

Parameter
Code:

0x006

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x08 = Invalid Function Code

Data Fields:

dd…dd

Drive name, a 64-character string.

Default:

" "

Advertising