2-106

Command Reference

Analog Output Override Enable/Disable

Analog Output Override Value

Format:

:aa04Efddmmcc<cr>

Parameter
Code:

0x04E

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x08 = Invalid Function Code

Data Fields:

dd

Enable/disable for overriding the analog output,
where:
0x00: Normal operation
0x01: Override the analog output.

Minimum
Value:

0x00

Maximum
Value:

0x01

Default:

0x00

Format:

:aa04Ffddddcc<cr>

Parameter
Code:

0x04F

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x04 = Data Below Minimum
0x05 = Data Above Maximum
0x08 = Invalid Function Code

Data Fields:

dddd

Analog output override value, in mV.

Minimum
Value:

-10000

Maximum
Value:

10000

Default:

0