Analog velocity scale, Analog velocity offset, Analog velocity scale analog velocity offset – Rockwell Automation 2098-DSD-xxx Ultra3000 Host Commands for Serial Interface User Manual

Page 37

Advertising
background image

Publication 2098-RM003A-EN-P October 2001

Command Reference

2-21

Analog Velocity Scale

Analog Velocity Offset

Format:

:aa118fddddddddcc<cr>

Parameter
Code:

0x118

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x04 = Data Below Minimum
0x05 = Data Above Maximum
0x08 = Invalid Function Code

Data Fields:

dddd

Analog velocity scale, in units of percentage of
maximum motor speed per 10 Volts.

Minimum
Value:

-200

Maximum
Value:

200

Default:

100

Format:

:aa047fddddcc<cr>

Parameter
Code:

0x047

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x04 = Data Below Minimum
0x05 = Data Above Maximum
0x08 = Invalid Function Code

Data Fields:

dddd

Analog velocity offset, in units of milliVolts.

Minimum
Value:

-10000

Maximum
Value:

10000

Default:

0

Advertising