Standard motor flag, Standard motor flag -70 – Rockwell Automation 2098-DSD-xxx Ultra3000 Host Commands for Serial Interface User Manual
Page 86
Advertising
Publication 2098-RM003A-EN-P October 2001
2-70
Command Reference
Standard Motor Flag
Format:
:aa095fddcc<cr>
Parameter
Code:
0x095
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x05 = Data Above Maximum
0x08 = Invalid Function Code
Data Fields:
dd
Motor flag, where:
0x00: Custom
0x01: Standard
Minimum
Value:
0x00
Maximum
Value:
0x01
Default:
0x00