Soft overtravel enable/disable, Soft overtravel enable/disable -53 – Rockwell Automation 2098-DSD-xxx Ultra3000 Host Commands for Serial Interface User Manual
Page 69
Publication 2098-RM003A-EN-P October 2001
Command Reference
2-53
Soft Overtravel Enable/Disable
Format:
:aa0DDfddcc<cr>
Parameter
Code:
0x0DD
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x05 = Data Above Maximum
0x08 = Invalid Function Code
Data Fields:
dd
Enable/disable control for the soft overtravel limit
checking, where:
0x00: Disable soft overtravel limit checking
0x01: Enable soft overtravel limit checking
Minimum
Value:
0x00
Maximum
Value:
0x01
Default:
0x00