Startup commutation, Encoder lines / meter, Startup commutation -73 encoder lines / meter -73 – Rockwell Automation 2098-DSD-xxx Ultra3000 Host Commands for Serial Interface User Manual

Page 89: Startup commutation encoder lines / meter

Advertising
background image

Publication 2098-RM003A-EN-P October 2001

Command Reference

2-73

Startup Commutation

Encoder Lines / Meter

Format:

:aa0E0fddcc<cr>

Parameter
Code:

0x0E0

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x05 = Data Above Maximum
0x08 = Invalid Function Code

Data Fields:

dd

Type of startup for sinusoidal commutation, where:
0x00: Self-sensing
0x01: Hall inputs.

Minimum
Value:

0x00

Maximum
Value:

0x01

Default:

0x00

Format:

:aa0E1fddddddddcc<cr>

Parameter
Code:

0x0E1

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x04 = Data Below Minimum
0x05 = Data Above Maximum
0x08 = Invalid Function Code

Data Fields:

dddddddd

Encoder lines/meter for a linear motor.

Minimum
Value:

4000

Maximum
Value:

10,000,000

Default:

100,000