Velocity motor, Velocity error, Current command – Rockwell Automation 2098-DSD-xxx Ultra3000 Host Commands for Serial Interface User Manual
Page 130: Average current

Publication 2098-RM003A-EN-P October 2001
2-114
Command Reference
Velocity Motor
Velocity Error
Current Command
Average Current
Format:
:aa085fddddddddcc<cr>
Parameter
Code:
0x085
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields:
dddddddd
Velocity feedback, in units of counts/second.
Format:
:aa086fddddddddcc<cr>
Parameter
Code:
0x086
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields:
dddddddd
Velocity error, in units of counts/second.
Format:
:aa087fddddcc<cr>
Parameter
Code:
0x087
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields:
dddd
Current command, in units of Amps*128.
Format:
:aa088fddddcc<cr>
Parameter
Code:
0x088
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields:
dddd
Command current after being filtered with a 100mS
time constant, in units of Amps*128.