Publication 2098-RM003A-EN-P October 2001

2-108

Command Reference

Run Status

Digital Input Status

Format:

:aa075fddcc<cr>

Parameter
Code:

0x075

Valid Function
Codes:

0x0 = Read Working Value

Valid Exception
Codes:

0x08 = Invalid Function Code

Data Fields:

dd

Run status, indicates if the drive is faulted, enabled,
or disabled, where:
0xFF: Disabled and not faulted
0x00:Enabled
0x01-0xFE:Faulted with error code as defined in
Appendix A.

Format:

:aa076fddddcc<cr>

Parameter
Code:

0x076

Valid Function
Codes:

0x0 = Read Working Value

Valid Exception
Codes:

0x08 = Invalid Function Code

Data Fields:

dddd

Digital input status. A bit set indicates the input is
active, with bit definitions as follows:
Bit 0:Input 1
Bit 1:Input 2
Bit 2:Input 3
Bit 3:Input 4
Bit 4:Input 5
Bit 5:Input 6
Bit 6:Input 7
Bit 7:Input 8