Rockwell Automation AADvance Controller Configuration Guide User Manual

Page 282

Advertising
background image

12-8

Document: 553633
ICSTT-RM405f-EN-P

Issue 07

Configuration Guide (AADvance Controller)


RTU

Remote terminal unit. The Modbus protocol

supported by the AADvance controller for
Modbus communications over serial links,
with the ability to multi-drop to multiple

slave devices.

S

safe state

A state which enables the execution of a
process demand. Usually entered after the

detection of a fault condition; it makes sure
the effect of the fault is to enable rather

than disable a process demand.

safety accuracy

The accuracy of an analogue signal within
which the signal is guaranteed to be free of

dangerous faults. If the signal drifts outside
of this range, it is declared faulty.

safety-critical state

A faulted state which prevents the
execution of a process demand.

sensor

A device or combination of devices that
measure a process condition. Examples are
transmitters, transducers, process switches

and position switches.

sequential function chart

An IEC 61131 language that divides the

process cycle into a number of well-defined
steps separated by transitions. See 'limited
variability language'.

SFF

Safe Failure Fraction. Given by (the sum of
the rate of safe failures plus the rate of
detected dangerous failures) divided by (the

sum of the rate of safe failures plus the rate
of detected and undetected dangerous

failures).

SIF

Safety Instrumented Function. A form of

process control that performs specified
functions to achieve or maintain a safe state
of a process when unacceptable or

dangerous process conditions are detected.

SIL

Safety Integrity Level. One of four possible
discrete levels, defined in IEC 61508 and IEC
61511, for specifying the safety integrity
requirements of the safety functions to be

allocated to a safety-related system. SIL4 has
the highest level of safety integrity; SIL1 has
the lowest.

The whole of an installation (of which the
AADvance system forms a part) must meet

these requirements in order to achieve an
overall SIL rating.

SNCP

SNCP (Safety Network Control Protocol) is

the Safety Protocol that allows elements of
an AADvance System to exchange data.

SNCP is a SIL 3 certified protocol which
provides a safety layer for the Ethernet
network making it a "Black Channel".

SNTP

Simple Network Time Protocol. Used for
synchronizing the clocks of computer
systems over packet-switched, variable-

latency data networks.

structured text

A high level IEC 61131-3 language with

syntax similar to Pascal. Used mainly to
implement complex procedures that cannot
be expressed easily with graphical languages.

synchronous

A data communications term describing a
serial transmission protocol. A pre-arranged

number of bits is expected to be sent across
a line per second. To synchronise the
sending and receiving machines, a clocking

signal is sent by the transmitting computer.
There are no start or stop bits.

Advertising