3 contr ol p a ra met ers 7.3 control parameters – HEIDENHAIN CNC Pilot 4290 User Manual

Page 360

Advertising
background image

7 Parameters

348

Continued

7.3 Contr

ol P

a

ra

met

ers

7.3

Control Parameters

Control Parameters

1 – Settings

■ÿ

Deactivate printer output:Using the PRINTA command in an NC

program, you can output data on a printer (see also control parameter
40, ...).

■ÿ

0: Output deactivated

■ÿ

1: Output activated.

■ÿ

Metric / Inch: Definition of the system of measurement

■ÿ

0: Metric system

■ÿ

1: Inch system

■ÿ

Display format of position display (actual value display)

■ÿ

0: Format 4.3 (4 integer positions, 3 decimal places)

■ÿ

1: Format 3.4 (3 integer positions, 4 decimal places)

■ÿ

In DIN PLUS programs, the unit of measure is defined in the

program head and is independent of the setting made here.

■ÿ

Restart the CNC PILOT after having changed the unit of

measure.

8 – Load monitoring settings

Evaluation: Load monitoring

■ÿ

Factor for torque limit value 1

■ÿ

Factor for torque limit value 2

■ÿ

Factor for work limit value

The CNC PILOT calculates as follows:

Limit value = reference value * factor for limit value

■ÿ

Minimum torque [% of rated torque]:

Reference values that remain below this value are raised to this
minimum torque value. This prevents that limit values are exceeded as
a result of minor torque differences.

■ÿ

Maximum file size [KB]:

If the data during measured value registration exceed the maximum
file size, the ”oldest” values are overwritten.
Approximate value: For one component per minute of program run time
approximately 12 KB.

10 – Post-process measuring

Evaluation: Post-process measuring

Activate measuring function

0: Postprocess measuring function off

1: Postprocess measuring function on – the CNC PILOT is ready to

receive data

Advertising