3 contr ol p a ra met ers 7.3 control parameters – HEIDENHAIN CNC Pilot 4290 User Manual
Page 360

7 Parameters
348
Continued
7.3 Contr
ol P
a
ra
met
ers
7.3
Control Parameters
Control Parameters
1 – Settings
■ÿ
Deactivate printer output:Using the PRINTA command in an NC
program, you can output data on a printer (see also control parameter
40, ...).
■ÿ
0: Output deactivated
■ÿ
1: Output activated.
■ÿ
Metric / Inch: Definition of the system of measurement
■ÿ
0: Metric system
■ÿ
1: Inch system
■ÿ
Display format of position display (actual value display)
■ÿ
0: Format 4.3 (4 integer positions, 3 decimal places)
■ÿ
1: Format 3.4 (3 integer positions, 4 decimal places)
■ÿ
In DIN PLUS programs, the unit of measure is defined in the
program head and is independent of the setting made here.
■ÿ
Restart the CNC PILOT after having changed the unit of
measure.
8 – Load monitoring settings
Evaluation: Load monitoring
■ÿ
Factor for torque limit value 1
■ÿ
Factor for torque limit value 2
■ÿ
Factor for work limit value
The CNC PILOT calculates as follows:
Limit value = reference value * factor for limit value
■ÿ
Minimum torque [% of rated torque]:
Reference values that remain below this value are raised to this
minimum torque value. This prevents that limit values are exceeded as
a result of minor torque differences.
■ÿ
Maximum file size [KB]:
If the data during measured value registration exceed the maximum
file size, the ”oldest” values are overwritten.
Approximate value: For one component per minute of program run time
approximately 12 KB.
10 – Post-process measuring
Evaluation: Post-process measuring
■
Activate measuring function
■
0: Postprocess measuring function off
■
1: Postprocess measuring function on – the CNC PILOT is ready to
receive data