10 .4 p a ra met ers and oper ating resour ces – HEIDENHAIN CNC Pilot 4290 User Manual
Page 434

10 Transfer
422
1
0
.4 P
a
ra
met
ers and Oper
ating Resour
ces
10.4.2 Saving Parameters and Operating
Resources
Data backup of parameters and operating
resources is conducted in two steps:
Create backup files (backup function)
Transfer backup files to an external system
(standard transfer function)
Restoring a data backup of parameters and
operating resources is also conducted in two steps:
Retrieving backup files from the external system
(Standard transfer function)
Integrating backup files in CNC PILOT (Restore
function)
Backup transfers the following files in the directory
BACKUP:
■
All parameter files
■
All operating resource data
■
All associated fixed-word lists
■
Maintenance system files
Parameters and operating resource files are
converted during backup.
Restore downloads all backup files into the
directory BACKUP (except maintenance system
files).
Call: Menu item “Parameter conversion—Backup /
Restore”
Back to Transfer menu
Operation
■
Arrow up/down (only in right window); moves the
cursor within the file list
■
Horizontal arrow keys: move from left to right
window and vice versa.
■
Enter (only in right window): displays the file
content—you close the file by pressing Enter
again (or ESC key)
(Only in right window): Sort by data or
file name
Make backup. All existing backup files
are deleted. Then the new backup
files are created.
Restore files.
Restore expects a complete file group saved by backup.
HEIDENHAIN recommends that you always treat a file
group saved by backup as a block.
Prerequisites for Restore:
■
Log in as system manager
■
The automatic mode must not be active
■
The backup files must be available in the BACKUP
directory
Maintenance-system files can be restored only by
trained service personnel.
Data backup soft keys
Define the sorting order
Update the file list
Make backup
Restore files