TROUBLESHOOTING

1-7

August 9, 2005

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

Ka a a

w s k

Ensure primary power supply is within specifications. Ensure primary power supply
cable is properly connected and is not damaged.

Ensure connectors at the 1KQ/1NR board are properly installed and not damaged.

Ensure the 1KP board fuses F1 and F2 are not open.

Replace the 1KQ/1NR board.

Ensure the power supplied to the AVR power supply is within specifications. Ensure
the power connector at the AVR power supply is properly connected and not dam-
aged.

Ensure to output voltages from the AVR power supply are within specifications.

Ensure the control power lamp is properly installed and is not defective.

Repair or replace disconnected or short-circuited wiring in the controller.