TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-196

August 9, 2005

Ka a a

w s k

ERROR CODE P4502

DEVNET) Already in that mode.

An attempt is made to change the operation mode setting, using the DEVNET com-
mand, to the mode that is currently set.

Ensure the correct parameter is set and re-execute the DEVNET command

.

_____________________________________________________________________

ERROR CODE P4503

Duplicate signal number.

The specified signal number cannot be used because the same signal number is cur-
rently set.

Specify a different signal number

.

_____________________________________________________________________

ERROR CODE P5000

Waiting weld completion.

Displayed when a command to change the step is entered while a welding sequence is
in progress (weld complete or retract/extend signal not received).

Reset the error, and release the wait condition.

Manually input weld complete or retract/extend signal.

_____________________________________________________________________

ERROR CODE P5001

Waiting retract or extend pos. input signal.

One of the following operations is attempted when the robot is processing a spot weld
sequence (waiting for the Retract/Extend signal after the weld complete signal is re-
ceived).
1. Cycle start (including EXECUTE, CONTINUE command).
2. Program selection or step change.
3. Record.

Input the Retract/Extend detection signal to the robot or access the wait override
screen on the teach pendant. Refer to the D Series Controller Operations and Pro-
gramming Manual for the wait override procedure.