Kawasaki D Series Controller MPVDCONTV113E-3 User Manual

Page 64

Advertising
background image

TROUBLESHOOTING

1-61

August 9, 2005

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

Ka a a

w s k

ERROR CODE E0108

Divided by zero.

Occurs when the system encounters a mathematical evaluation that involves division by
“0”. Typically associated with the FRAME function and circular interpolation.

Check data source for calculations.

_____________________________________________________________________

ERROR CODE E0109

Floating point overflow.

Occurs when the system encounters a numeric floating point overflow in using arith-
metic (+, -, *, /) or logical (AND, OR, etc.) operators. This also occurs when converting a
numeric argument to an integer value.

Correct the program. Integer values with full precision ranges are from -16,777,216
to 16,777,216. For more information refer to the D Series Controller AS Language
Reference Manual.

_____________________________________________________________________

ERROR CODE E0110

String too long.

Character strings associated with arithmetic or comparative operators or the LEN func-
tion are too long (255 character maximum).

Correct the character string.

_____________________________________________________________________

ERROR CODE E0111

Attempted operation with neg. exponent.

Numeric values that have exponents must be positive in value.

Correct equations in program.

_____________________________________________________________________

ERROR CODE E0112

Too complicated expression.

Encountered numeric calculation too complex to be evaluated.

Simplify mathematical equations.

_____________________________________________________________________

Advertising