Kawasaki D Series Controller MPVDCONTV113E-3 User Manual

Page 182

Advertising
background image

TROUBLESHOOTING

1-179

August 9, 2005

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

Ka a a

w s k

ERROR CODE P1034

This program is not editable.

The auto load measurement program cannot be edited.

Use a program name that does not include the auto load measurement program
name.

_____________________________________________________________________

ERROR CODE P1035

Record inhibited. Set [record accept] and operate again.

Displayed when an attempt is made to enter data, but Inhibit Record in auxiliary function
0802 is set to inhibit.

Change the setting of the Inhibit Record in AUX 0802.

_____________________________________________________________________

ERROR CODE P1036

Program change inhibited. Set [Accept] and operate
again.

Displayed when an attempt is made to enter data, but Program Change in auxiliary
function 0802 is set to inhibit.

Change the setting of the Program Change in AUX 0802.

_____________________________________________________________________

ERROR CODE P1037

Program name cannot be called “calib_load_”.

Use a program name that does not include

“calib_load_

“.

_____________________________________________________________________

ERROR CODE P1038

Program does not exist.

Main causes include:
1. Non-existing program is selected.
2. Program check operation or cycle start is executed without a program selected.

Select an existing program before executing program check or cycle start.

_____________________________________________________________________

Advertising