3 replacement procedure for power block unit, 1 1kc power block unit – Kawasaki D Series Controller MPVDCONTV113E-3 User Manual

Page 239

Advertising
background image

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

2-10

Ka a a

w s k

2.3

REPLACEMENT PROCEDURE FOR POWER BLOCK UNIT

This section describes the replacement procedure for the power block unit mounted in the

controller.

Four types of power block are available as described below.

1. 1KC: Power block for large robot (six axes)

2. 1KD: Power block for small robot (six axes)

3. 1KL: Optional power block for large motor (single axis)

4. 1KR: Optional power block for small motor (single axis)

Replacement procedures for the 1KC and 1KD are described in this section.

2.3.1 1KC POWER BLOCK UNIT

DANGER

High voltage is applied in the power block unit. Do

not touch any connector pin during replacement.

CAUTION

Power block unit weighs approx. 20kg. Be careful not to

incur back injury, etc. when removing the power block unit.

WARNING

Do not remove the screws or cover from the front of the

power block unit. This is a high voltage area and there is

a danger of electric shock.

DANGER

Before starting replacement work, turn OFF the control

power and wait at least seven minutes.

Advertising