TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-110

August 9, 2005

Ka a a

w s k

ERROR CODE E1149

Cannot open setting data, so cannot set to shipment state.

When “2: Setting to shipment state” is selected from the initialization screen, a data file
in the setting file (ini_load.cmd) in the 1KA board memory could not be opened.

Ensure the proper setting file

(ini_load.cmd)

is loaded into the 1KA board memory

.

_____________________________________________________________________

ERROR CODE E1150

Cannot read setting data, so cannot set to shipment state.

When “2: Setting to shipment state” is selected from the initialization screen, a data file
in the setting file (ini_load.cmd) in the 1KA board memory could not be decoded.

Ensure the proper setting file

(ini_load.cmd)

is loaded into the 1KA board memory

.

If the proper setting file (ini_load.cmd) is loaded replace the 1KA board.

_____________________________________________________________________

ERROR CODE E1151

Too much data for setting to the shipment state.

When “2: Setting to shipment state” is selected from the initialization screen, more than
10 data files are in the setting file (ini_load.cmd) in the 1KA board memory.

Ensure 10 or less data files are in the setting file

(ini_load.cmd)

loaded into the 1KA

board memory

.

_____________________________________________________________________

ERROR CODE E1152

Name of setting data for shipment state is too long.

When “2: Setting to shipment state” is selected from the initialization screen, the name
of a data file in the setting file (ini_load.cmd) in the 1KA board memory exceeds eight
characters, or the file extension exceeds four characters.

Ensure the file name and extension contains the proper number of characters.

_____________________________________________________________________

ERROR CODE E1153

Power sequence board detects error. (Code=XX)

An error is detected by the 1KP board but the code (Code=XX) could not be interpreted
by the AS software.

Replace the 1KP board

.

If this error recurs after replacing the 1KP board contact KRI customer service.

_____________________________________________________________________