Kawasaki D Series Controller MPVDCONTV113E-3 User Manual

Page 70

Advertising
background image

TROUBLESHOOTING

1-67

August 9, 2005

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

Ka a a

w s k

ERROR CODE E1010

Power sequence board detects error.

An error signal, not classified through the error summary, is generated by the 1KP board
and is sent to the 1KB board. This error occurs when the error signal sent from the 1KP
board is not recognized by the AS software.

Main causes include:
1. The error detection function of the 1KP power sequence board does not correspond

to the error processing function of the AS software.

2. AS software is not installed correctly or is corrupt.
3. Defective 1KP power sequence board.
4. Defective 1KB board.

Ensure the correct version of AS software is installed.

Replace the 1KP power sequence board.

Replace the 1KB board.

_____________________________________________________________________

ERROR CODE E1011

Built-in sequence board is not installed.

Installation of the built-in (Sharp) sequence board is checked at controller power-up.

Install the built-in (Sharp) sequence board.

Ensure the built-in (Sharp) sequence board is properly installed.

If the built-in (Sharp) sequence board is not used, change the settings so the control-
ler does not check for the built-in (Sharp) sequence board.

The PC3JB board

(TOYOPUC PLC)

is not recognized

as a built-in sequence board.

_____________________________________________________________________

ERROR CODE E1012

RI/O board or C-NET board is not installed.

This error occurs at controller power-up and the first address of the RI/O board is not
read (1GW/1HW, 1FS etc.).
1. The RI/O or C-Net board is not installed.
2. Defective RI/O or C-Net board.

Ensure the RI/O or C-Net board is installed.

Replace the RI/O or C-Net board.

_____________________________________________________________________

NOTE

Advertising