TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-68

August 9, 2005

Ka a a

w s k

ERROR CODE E1013

InterBus board is not installed.

The 1JF board is not installed.

Ensure the 1JF board is properly installed

.

Replace the 1JF board.

_____________________________________________________________________

ERROR CODE E1016

No. XX CC-LINK board is not installed.

The specified number 1HS board is not installed.

Installed the specified number 1HS board.

Ensure the specified number 1HS board is properly installed.

Replace the specified number 1HS board.

_____________________________________________________________________

ERROR CODE E1017

PLC error. Error code is Hex. XX.

This error occurs when a PC3JB (TOYOPUC) internal error is present (program memory
check sum error, parameter setting error, etc.).

Refer to the PC3JB (TOYOPUC) manual for the code (Hex. XX).

Replace the PC3JB (TOYOPUC).

_____________________________________________________________________

ERROR CODE E1018

INTER-BUS status error.

A processing error such as cable disconnection is detected at the 1JF board during
communication.

Refer to the 1JF board manual for information for checking error state displayed by
the front LED

.

Replace the 1JF board.

_____________________________________________________________________

ERROR CODE E1020

External equipment is abnormal.

An abnormality in peripheral equipment is detected by the PC3JB board

(TOYOPUC).

Check PC3JB board (TOYOPUC) peripheral equipment connections.

Ensure proper installation and connection of peripheral equipment.

_____________________________________________________________________

Advertising