TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-16

August 9, 2005

Ka a a

w s k

ERROR CODE D0005

[ARM CONTROL BOARD] CPU BUS error. (PC=XX)

On the 1KB board, a bus error occurs (in the VME bus line, detected by AS software);
data processing is not completed normally. This error is caused by defective AS soft-
ware, defective 1KB board, or noise related malfunction.

PC Error Display Example:

Error (D0005) [ARM CONTROL BOARD] CPU BUS error Code=1

Task (Pc01) Stop SIG=00070004 [NMI(

)] PC=*****

VME BUS ERROR

Indicates the place the error occurred

Refer to the error message displayed on a PC interfaced with the controller.

Cycle controller power OFF and ON. Do not initialize the controller

.

If a message for

initialization is displayed, select “NO”.

Ensure the correct 1KB board software is loaded into the 1KA board.

Replace the 1KB board.

If the above steps do not correct the error, contact KRI customer service

.

_____________________________________________________________________

ERROR CODE D0900

Teach data is broken.

The program storage area of the system memory is damaged and is not linking data
correctly.

Main causes include:
1. Loss of memory battery back-up.
2. Noise related malfunction.
3. Defective 1KA board.

Set the 1KA board switch SW2-8 to ON and initialize the memory, do not use AUX
0805 or SYSINIT command. Reload the robot program data.

Check the memory backup battery. Replace if necessary (3.3 VDC or less). When
battery voltage drops to 3.3 VDC, or less, error W1010 is displayed.

Replace the 1KA board if the error recurs.

_____________________________________________________________________